GSO ISO/TS 16422-3:2025

ISO/TS 16422-3:2023
Gulf Standard   Current Edition · Approved on 14 October 2025

Pipes and joints made of oriented unplasticized poly(vinyl chloride) (PVC-O) for the conveyance of water under pressure — Part 3: Fittings

GSO ISO/TS 16422-3:2025 Files

GSO ISO/TS 16422-3:2025 Scope

This document specifies the characteristics of solid-wall oriented unplasticized poly(vinyl chloride) (PVC-O) fittings for piping systems intended to be used underground or above ground where protected from direct sunlight, for water supply, buried drainage, sewerage, treated wastewater and irrigation under pressure. This document is applicable to double sockets, repair couplings, reducers and to non-end load bearing elbows only. This document is not applicable to tees, flange adaptors, etc.

NOTE            For double sockets, repair couplings, and reducers, there are no special fittings designs for end-load bearing applications. However, restrained gaskets can be used for end-load bearing applications. In this case, the requirements of ISO 16422-5 are applicable.

This document also specifies the test parameters for the test methods referred to in this document.

In conjunction with ISO 16422-1 and ISO 16422-5, this document is applicable to oriented PVC-O pipes with or without an integral socket, intended to be used for the following:

a)       water mains and services lines;

b)       conveyance of water for both outside and inside buildings;

c)        drainage, sewerage and treated wastewater under pressure;

d)       irrigation under pressure.

This document is applicable to piping systems intended for the supply of water under pressure up to and including 25 °C (cold water), intended for human consumption and for general purposes as well as for wastewater under pressure.

This document is also applicable to components for the conveyance of water and wastewater up to and including 45 °C. For temperatures between 25 °C and 45 °C, see ISO 16422-2, Figure C.1.

The piping system according to this document is intended for the conveyance of cold water up to pressure of 25 bar[1] and especially in those applications where special performance requirements are needed, such as impact loads and pressure fluctuations, up to pressure of 25 bar.

[1]  1 bar =0,1 MPa=105 Pa; 1 MPa= 1 N/mm2

Best Sellers From Mechanical Sector

GSO 42:2015
 
Gulf Technical Regulation
MOTOR VEHICLES - GENERAL REQUIREMENTS
GSO 159:1993
 
Gulf Technical Regulation
MOTOR VEHICLES – DIMENSIONS AND WEIGHTS
GSO 98:1988
 
Gulf Technical Regulation
MOTOR VEHICLES- FLAMMABILITY OF INTERIOR MATERIALS AND THEIR TESTING METHODS
GSO 2698:2022
 
Gulf Standard
Technical Requirements for Electric Vehicles

Recently Published from Mechanical Sector

GSO ISO 24596:2026
ISO 24596:2024 
Gulf Standard
Drinking water, wastewater and stormwater systems and services — Guidelines for the planning and implementation of infrastructure hardening for water and wastewater systems
GSO ISO/TR 7035-2:2026
ISO/TR 7035-2:2024 
Gulf Standard
Design and asset management of DIP for water application — Part 2: Design, installation and operation
GSO ECE 148:2026
ECE 148:2023 
Gulf Standard
Uniform provisions concerning the approval of light-signalling devices (lamps) for power-driven vehicles and their trailers
GSO ASTM D4195:2026
ASTM D4195:23 
Gulf Standard
Standard Guide for Water Analysis for Reverse Osmosis and Nanofiltration Application